Abstract


In this study, an automatic registration system was developed that can measure 3 dimensional position and orientation of multi-range fiducials automatically using a camera, laser range finder and motion bases connected to a computer. Result of the experimental evaluation shows that the measurement takes about 50 seconds per marker and RMSE (Root Mean Square Error) of the position and orientation measurement are 3.5 mm and 1.2 degrees respectively.